Skip links

5 As-Built Drawing Options for Las Vegas Commercial Renovations

Laser scanner capturing existing conditions inside a commercial space before renovation

A retail tenant improvement may need dimensioned floor plans and a reflected ceiling plan. A restaurant remodel may also need the location of existing ducts and utility connections. An occupied hotel or casino renovation may call for a Revit model so architects and engineers can coordinate the new design around existing structure and building systems.

Start with the decisions your design team needs to make. If they’re changing the layout, start with floor plans. If the work affects lighting, ceilings, or storefronts, add ceiling plans, elevations, or sections. If new equipment must fit around existing building systems, consider visible MEP documentation or a Revit model with those systems included.

Which as-built drawings does your renovation need?

Match the deliverables to what your design team needs to verify.

As-built option What it documents When to use it
1. Dimensioned CAD floor plans Walls, doors, columns, and room dimensions Retail or office buildouts focused on layout
2. Floor plans and reflected ceiling plans Layout plus ceiling features such as soffits, lights, and diffusers Retail, restaurant, and hotel remodels that affect ceilings
3. Elevations and sections Vertical dimensions, openings, and relationships between levels Storefronts, tall lobbies, and spaces with changes in ceiling height
4. Visible MEP documentation Accessible ducts, piping, equipment, and other systems included in the scope Commercial kitchens, mechanical rooms, and above-ceiling coordination
5. As-built Revit models Existing architecture and any structural or MEP elements specified in the scope Hotel, casino, and complex commercial renovations where multiple disciplines work in BIM

1. Dimensioned CAD floor plans

Dimensioned CAD floor plan of an existing retail tenant space

A dimensioned floor plan is a practical starting point when the main question is what fits in the existing space. For a retail tenant improvement, it can help the architect lay out display areas, back-of-house rooms, partitions, and circulation around existing columns and openings.

Ask your architect which parts of the suite and adjacent areas they need measured. If the team designs in AutoCAD, request editable DWG files and a PDF for review.

Related: Scan-to-CAD services

2. Floor plans and reflected ceiling plans

Reflected ceiling plan showing lights, soffits, and diffusers in a restaurant

Add a reflected ceiling plan when the project affects lights, ceiling heights, soffits, or visible fixtures. For example, a restaurant moving its service counter may need to coordinate the new layout with pendant lights, ceiling transitions, and supply diffusers.

A reflected ceiling plan records features visible from below. If the engineer needs to trace ductwork or piping above the ceiling, include that area in the fieldwork scope separately.

Related: As-built drawing services and sheet types

3. Elevations and sections

As-built elevation and section drawings of a storefront and hotel lobby

Elevations and sections help when a floor plan can’t answer a height question. A storefront designer may need the height and width of existing glazing and door openings. A hotel lobby designer may need a section showing how a soffit, balcony, or tall feature wall relates to the floor and ceiling.

Identify the walls and locations that matter to the renovation. A section through the planned work is more useful than one taken through an unrelated part of the building.

4. Visible MEP documentation

Visible MEP documentation of ducts, piping, and equipment above a commercial ceiling

A new kitchen hood or relocated mechanical unit may have to fit around existing ducts, pipes, and equipment. Ask the engineer which mechanical, electrical, and plumbing systems they need documented, in which rooms, and at what level of detail.

Coordinate access to the ceiling plenum, roof, or mechanical room before scanning. Laser scanning captures visible surfaces from accessible positions. If a route disappears behind a closed wall or inaccessible ceiling, document that limit so the design team knows where it needs additional verification.

Related: MEP documentation services

5. As-built Revit models

As-built Revit model of a hotel lobby created from a registered point cloud

A Revit model is useful when architects and engineers want to coordinate their designs around existing conditions in BIM. A lobby refresh might need architectural geometry and ceiling heights. A casino or hotel renovation with overhead work may also need visible structure and selected MEP systems modeled.

Agree on which elements the Revit model should contain. If the design team also wants to reference the measured surfaces directly, request the registered point cloud.

Related: Scan-to-BIM services · Registered point cloud services

Las Vegas Example: Scanning an Occupied ARIA Hotel Lobby

For a lobby renovation at ARIA, our team scanned during off-peak hours and delivered a point cloud, a LOD 300 Revit model, and ceiling documentation. The project illustrates why an occupied hospitality renovation can have two connected requirements: the right documentation for the design team and an access plan that works around property operations. See the ARIA lobby case study.

People Also Ask: As-Built Drawings for Renovation FAQ

What as-built drawings do I need for a tenant improvement permit set?

Start with your architect’s existing-condition sheet list. A dimensioned floor plan is a common starting point. Depending on the work, your architect may also need reflected ceiling plans, elevations, sections, or visible building systems. Those drawings give the design team a measured baseline for preparing the proposed permit documents.

Can you create as-built drawings without the original plans?

Yes. On-site laser scanning can capture visible, accessible existing conditions even when original drawings are missing. If older plans are available, they can help identify areas to check during fieldwork.

Is a reflected ceiling plan enough to show existing ductwork?

A reflected ceiling plan commonly shows visible ceiling features such as diffusers and grilles. To document duct routes above the ceiling, include visible above-ceiling MEP in the scope and arrange access to the areas the engineer needs.

Can a hotel or casino be scanned while it’s open?

Yes, when the property can provide access to the relevant areas. Coordinate scan hours, restricted spaces, and any escort requirements with the property team. At ARIA, off-peak access was part of the fieldwork plan.

Should I order AutoCAD drawings or a Revit model?

Choose AutoCAD DWGs when the design team needs editable 2D sheets. Choose Revit when the team needs to coordinate in BIM around existing architecture, structure, or building systems. Confirm the file format with the people who will use it.

Planning a Commercial Renovation in Las Vegas or Henderson?

Send LiDAR Precise Plans the property address and whatever scope your design team has provided. We can help identify the drawings or model to include.

Get a Free Quote

27 Years of Experience • Sub-Inch LiDAR Accuracy